Standard

IEEE C37.59-2018

Actuel
Aperçu L'aperçu n'est pas disponible

Amendements et versions existants ou nouveaux doivent être achetés séparément.

Langue
Format

Résumé

Revision Standard - Active. Directions and requirements are provided for the conversion of qualified power switchgear equipment. Examples such as low-voltage power circuit breakers; high-voltage outdoor, and medium-voltage indoor drawout power circuit breakers; medium-voltage fused contactors; medium-voltage ground and test devices; medium-voltage fused load interrupter switches; and metal-enclosed switchgear are covered in this standard. Existing design standards are referenced with appropriate guidance on design testing necessary to design-verify the conversions. Reconditioning, which concerns the maintenance of existing equipment without alteration, is not covered.

Spécifications des produits

  • Standard de IEEE
  • Publié:
  • Type de document: IS
  • Pages
  • Editeur: IEEE
  • Distributeur: IEEE
  • ICS: 29.130.01
  • Comité national: IEEE Power and Energy Society / Switchgear

Relations produit

  • Référencé par: IEEE 62271-37-013-2021
  • Référencé par: IEEE 62271-37-013-2021
  • Référence: IEEE C37.20.7-2017
  • Référence: IEEE C37.20.7-2017
  • Référence: IEEE C37.13.1-2016
  • Référence: IEEE C37.13.1-2016
  • Référence: IEEE C37.20.10-2016
  • Référence: IEEE C37.20.10-2016
  • Référence: IEEE C37.13-2015
  • Référence: IEEE C37.13-2015
  • Référence: IEEE C37.20.2-2015
  • Référence: IEEE C37.20.1-2015
  • Référence: IEEE C37.20.1-2015
  • Référence: IEEE C37.14-2015
  • Référence: IEEE C37.14-2015
  • Référence: IEEE C37.20.6-2015
  • Référence: IEEE C37.20.6-2015
  • Référence: IEEE C37.20.3-2013
  • Référence: IEEE C37.20.3-2013
  • Référence: IEEE C37.20.4-2013
  • Référence: IEEE C37.20.4-2013
  • Référence: IEEE C37.17-2012
  • Référence: IEEE C37.48.1-2011
  • Référence: IEEE C37.06-2009
  • Révise: IEEE C37.59-2007
  • Référence: IEEE C37.48-2005
  • Référence: IEEE C37.48-2005
  • Référence: IEEE C37.09-1999
  • Référence: IEEE C37.04-1999
  • Référence: UL 347, Standard for Medium-Voltage AC Contactors, Controllers, and Control Centers.
  • Référence: ANSI C37.50, American National Standard for Switchgear—Low-Voltage AC Power Circuit Breakers Used in Enclosures—Test Procedures.
  • Référence: ANSI C37.58, American National Standard for Switchgear—Indoor AC Medium-Voltage Switches for Use in Metal-Enclosed Switchgear—Conformance Test Procedures.
  • Référence: ANSI Z535.4, American National Standard for Product Safety Signs and Labels.
  • Référence: UL 94, Standard for Tests for Flammability of Plastic Materials for Parts in Devices and Appliances.
  • Référence: ANSI C37.51, American National Standard for Switchgear—Metal-Enclosed Low-Voltage AC Power Circuit Breaker Switchgear Assemblies—Conformance Test Procedures.
  • Référence: NFPA 70E®, Standard for Electrical Safety in the Workplace.
  • Référence: UL 2876, Outline of Investigation for Remote Racking Devices for Switchgear and Controlgear
  • Référence: UL 50V, Outline of Investigation for Infrared Viewports.
  • Référence: ANSI C37.55, American National Standard for Switchgear—Medium-Voltage Metal-Clad Assemblies—Conformance Test Procedures.
  • Référence: UL 1066, Standard for Low-Voltage AC and DC Power Circuit Breakers Used in Enclosures.
  • Référence: IEC/IEEE 62271-37-013, High-voltage switchgear and controlgear—Part 37-013: Alternating-current generator circuit breakers.3,4
  • Référence: UL 508, Standard for Industrial Control Equipment.
  • Référence: ANSI C37.54, American National Standard for Indoor Alternating Current High-Voltage Circuit Breakers Applied as Removable Elements in Metal-Enclosed Switchgear—Conformance Test Procedures.
  • Référence: NFPA 70®, National Electrical Code®(NEC®).