Standard

IEEE 1019-2013

Révisé

Amendements et versions existants ou nouveaux doivent être achetés séparément.

Langue
Format

Résumé

Revision Standard - Superseded. Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile or polyethylene jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96 ºC (205 ºF) maximum for nitrile or a maximum minimum of –10 ºC (14 ºF) minimum. Conductors, insulation, assembly and with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.

Spécifications des produits

  • Standard de IEEE
  • Publié:
  • Type de document: IS
  • Pages
  • Editeur: IEEE
  • Distributeur: IEEE
  • ICS: 29.060.20
  • Comité national: IEEE Industry Applications Society / Petroleum and Chemical Industry

Relations produit

  • Révisé par: IEEE 1017.3-2021
  • Référence: IEEE 1017-2013
  • Révise: IEEE 1019-2004
  • Référence: ICEA S-61-402/NEMA WC5, Thermoplastic-Insulated Wire and Cable.
  • Référence: ASTM D412, Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension.
  • Référence: ASTM B33, Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purpose.
  • Référence: ANSI/ICEA S-96-659/NEMA WC71, Nonshielded Cables Rated 2001 – 5000 Volts.
  • Référence: ASTM A90, Standard Test Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings.
  • Référence: ICEA S-19-81/NEMA WC3, Rubber Insulated Wire and Cable.
  • Référence: API RP 11S5, Recommended Practice for Application of Electric Submersible Pump Cable Systems.
  • Référence: ASTM B3, Standard Specification for Soft or Annealed Copper Wire.
  • Référence: API RP 11S4, Recommended Practice for Sizing and Selection of Electric Submersible Pump Installation.
  • Référence: API RP 11S3, Recommended Practice for Electric Submersible Pump Installations.
  • Référence: ASTM B189, Standard Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for Electrical Purposes.
  • Référence: ASTM B8, Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.
  • Référence: API RP 11S6, Recommended Practice for Testing of Electric Submersible Pump Cable Systems.
  • Référence: ASTM B496, Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors.