IEEE 1019-2004

Révisé

Note: Version actuelle: IEEE 1019-2013

Amendements et versions existants ou nouveaux doivent être achetés séparément.

Langue
Format

Résumé

Revision Standard - Superseded. Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96 ºC (205 ºF) for nitrile or a maximum of –10 ºC (14 ºF). Conductors, insulation, assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered.

Spécifications des produits

  • Standard de IEEE
  • Publié:
  • Type de document: IS
  • Pages
  • Editeur: IEEE
  • Distributeur: IEEE
  • ICS: 29.060.20
  • Comité national: IEEE Industry Applications Society / Petroleum and Chemical Industry

Relations produit

  • Révisé par: IEEE 1019-2013
  • Référence: IEEE 1017-2004
  • Référencé par: IEEE 1017-2004
  • Révise: IEEE 1019-1991
  • Référence: ASTM B33, Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purpose.
  • Référence: ICEA S-19-81/NEMA WC 3, Rubber-Insulated Wire and Cable for the Transmission and Distribution of Electrical Energy.4
  • Référence: API RP 11S4, Recommended Practice for Sizing and Selection of Electric Submersible Pump Installation,3rd ed.
  • Référence: or Soft.
  • Référence: API RP 11S6, Recommended Practice for Testing of Electric Submersible Pump Cable Systems, 1st ed.
  • Référence: ASTM B8, Standard Specification for Concentric-Lay—Stranded Copper Conductors, Hard, Medium-Hard,
  • Référence: ASTM B189, Standard Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for
  • Référence: ASTM D412, Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension.
  • Référence: Electrical Purposes.
  • Référence: ICEA S-61-402/NEMA WC 5, Thermoplastic-Insulated Wire and Cable for the Transmission and Distribution of Electrical Energy.
  • Référence: ASTM A90, Standard Test Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings.3
  • Référence: ASTM B3, Standard Specification for Soft or Annealed Copper Wire.
  • Référence: API RP 11S3, Recommended Practice for Electric Submersible Pump Installations, 2nd ed.2
  • Référence: ASTM B496, Standard Specification for Compact Round Concentric-Lay—Stranded Copper Conductors.