Standard

IEEE 404-2006

Revised

Note: Latest version: IEEE 404-2022

Existing or new amendments and versions must be purchased separately.

Language
Services

Abstract

Revision Standard - Superseded. This standard establishes electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2500 to 500 000V. In addition, it defines test requirements for cable jacket and cable shield restoration devices. It also defines a variety of common joint constructions. This standard is designed to provide uniform testing procedures that can be used by manufacturers and users to evaluate the ability of underground power cable joints, and associated cable shield and cable jacket restoration components, to perform reliably in service.

Products specifications

  • Standard from IEEE
  • Published:
  • Document type: IS
  • Pages
  • Publisher: IEEE
  • Distributor: IEEE
  • ICS: 29.120.20
  • National Committee: IEEE Power and Energy Society / Insulated Conductors

Product Relations

  • Revised by: IEEE 404-2012
  • Referred by: IEEE 592-2007
  • Refers: IEEE 82-2002
  • Revises: IEEE 404-2000
  • Refers: IEEE C37.09-1999
  • Refers: IEEE 592-1990
  • Refers: IEEE 575-1988
  • Refers: AEIC CS4-Specifications for Impregnated-Paper-Insulated Low and Medium Pressure Self-Contained Liquid Filled Cable
  • Refers: ICEA P-45-482-Short-Circuit Performance of Metallic Shields and Sheaths on Insulated Cable
  • Refers: ASTM D412-98-Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers
  • Refers: ASTM D149-97a-Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies
  • Refers: AEIC CS6-Specifications for Ethylene Propylene Rubber Insulated Shielded Power Cables Rated 5 Through 69 kV.
  • Refers: AEIC CS7-Specifications for Crosslinked Polyethylene Insulated Shielded Power Cables Rated 69 Through 138 kV
  • Refers: ASTM D4496-04-Standard Test Method for DC Resistance or Conductance of Moderately Conductive Materials
  • Refers: ANSI C119.4-Electric Connectors—Connectors for Use Between Aluminum-to-Aluminum or Aluminum-to-Cooper Bare Overhead Connectors
  • Refers: ASTM D4325-02-Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes
  • Refers: AEIC CS2-Specification for Impregnated Paper and Laminated Paper Polypropylene Insulated Cable, High Pressure Pipe Type
  • Refers: AEIC CS3-Specifications for Impregnated-Paper-Insulated Metallic Sheathed Cable, Low Pressure Gas-Filled Type
  • Refers: ICEA P-32-382-Short-Circuit Characteristics of Insulated Cable
  • Refers: AEIC CS8-Specification for Extruded Dielectric Shielded Power Cables Rated 5 Through 46 kV
  • Refers: AEIC CS1-Specifications for Impregnated Paper-Insulated Metallic-Sheathed Cable, Solid Type.
  • Refers: ASTM D991-89-Standard Test Method for Rubber Property-Volume Resistivity of Electrically Conductive and Antistatic Products