Standard

IEEE C37.122.1-2014

Actuel

Amendements et versions existants ou nouveaux doivent être achetés séparément.

Langue
Format

Résumé

Revision Standard - Active. Information of special relevance to planning, design, testing, installation, operation and maintenance of gas-insulated substations (GIS) and equipment is provided in this guide, which is intended to supplement IEEE Std C37.122(TM). This guide is applicable to all gas-insulated substations (GIS) above 52 kV. However, the importance of topics covered varies with application category. For example, the issues related to advanced field test techniques and very fast transients (VFT) are of particular interest for extra-high voltage (EHV) gas-insulated substations (GIS).

Spécifications des produits

  • Standard de IEEE
  • Publié:
  • Type de document: IS
  • Pages
  • Editeur: IEEE
  • Distributeur: IEEE
  • ICS: 27.100
  • Comité national: IEEE Power and Energy Society / Substations

Relations produit

  • Référencé par: IEEE C37.123-2023
  • Référencé par: IEEE C37.123-2023
  • Référencé par: IEEE C37.122.2-2022
  • Référencé par: IEEE C37.122.7-2021
  • Référencé par: IEEE C37.123-2016
  • Référencé par: IEEE C37.123-2016
  • Référence: IEEE C37.122.3-2011
  • Référence: IEEE 1300-2011
  • Référence: IEEE C37.011-2011
  • Référence: IEEE C37.017-2010
  • Référence: IEEE C37.122-2010
  • Référence: IEEE C37.06-2009
  • Référence: IEEE C37.301-2009
  • Référence: IEEE C37.100.1-2007
  • Référence: IEEE 693-2005
  • Référence: IEEE C37.010-1999
  • Référence: IEEE C37.09-1999
  • Référence: IEEE C37.04-1999
  • Révise: IEEE C37.122.1-1993
  • Référence: IEC 61850, Communication Networks and Systems in Substations.
  • Référence: IEC 60270, High-voltage test techniques--Partial discharge measurements.
  • Référence: IEC 62271-100, High-Voltage Switchgear and Controlgear--Part 100: High-Voltage Alternating Current Circuit Breakers.
  • Référence: IEC 62271-203, High-Voltage Switchgear and Controlgear--Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV.
  • Référence: IEC 62271-205, High-Voltage Switchgear and Controlgear--Part 205: Compact Switchgear Assemblies for Operation at Rated Voltages Above 52 kV.
  • Référence: IEC 62271-209, High-Voltage Switchgear and Controlgear--Part 209: Cable connections for Gas-Insulated Metal-Enclosed Switchgear for Rated Voltages Above 52 kV--Fluid-Filled and Extruded Insulation Cables—Fluid-Filled and Dry-Type Cable-Terminations.
  • Référence: IEC 62271-102, High-Voltage Switchgear and Controlgear--Part 102: High Voltage Alternating Current Disconnectors and Earthing Switches.
  • Référence: CIGRE 69-1992, General Guidelines for the Design of Outdoor AC Substations.
  • Référence: CIGRE 525, Risk Assessment on Defects in GIS Based on PD Diagnostics.
  • Référence: CIGRE 444, Guidelines for Unconventional Partial Discharge Measurements.
  • Référence: ASTM D2472-00 Standard Specification for Sulfur Hexafluoride.
  • Référence: IEC 62271-211, High-Voltage Switchgear and Controlgear-Part 211: Direct Connection Between Power Transformers and Gas-Insulated Metal Enclosed Switchgear for Rated Voltages Above 52 kV.
  • Référence: CIGRE 390, Evaluation of Different Switchgear Technologies (AIS, MTS, GIS) for Rated Voltages of 52 kV and Above.