Revision Standard - Active. The technical requirements for the design, fabrication, testing, and installation of a gas insulated substations are covered. The parameters to be supplied by the purchaser are set, and the technical requirements for the design, fabrication, testing, and installation details to be furnished by the manufacturer are established.

Spécifications des produits

  • Standard de IEEE
  • Publié:
  • Type de document: IS
  • Pages
  • Editeur: IEEE
  • Distributeur: IEEE
  • ICS: 27.100
  • Comité national: IEEE Power and Energy Society / Substations

Relations produit

  • Référencé par: IEEE C37.123-2023
  • Référencé par: IEEE C37.123-2023
  • Référencé par: IEEE C37.122.2-2022
  • Référencé par: IEEE C37.122.7-2021
  • Référence: IEEE C37.017-2020
  • Référence: IEEE 48-2020
  • Référence: IEEE C37.04-2018
  • Référence: IEEE C37.09-2018
  • Référence: IEEE 693-2018
  • Référence: IEEE C37.100.1-2018
  • Référence: IEEE C37.015-2017
  • Référence: IEEE C37.24-2017
  • Référence: IEEE C37.21-2017
  • Référence: IEEE C37.010-2016
  • Référence: IEEE C57.13-2016
  • Référence: IEEE 837-2014
  • Référence: IEEE C37.012-2014
  • Référence: IEEE C37.122.3-2011
  • Référence: IEEE 1300-2011
  • Révise: IEEE C37.122-2010
  • Référence: IEEE C37.301-2009
  • Référence: IEEE C37.100-1992
  • Référence: IEEE 315-1975
  • Référence: CENELEC EN 50052, High-voltage switchgear and controlgear--Gas-filled cast aluminium alloy enclosures.
  • Référence: CENELEC EN 50064, Wrought Aluminum and Aluminum-Alloy Enclosures for Gas-Filled High-Voltage Switchgear and Controlgear.
  • Référence: IEC 62271-209, High-voltage switchgear and controlgear--Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV--Fluid-filled and extruded insulation cables--
  • Référence: IEC 62271-203:2011, High-voltage switchgear and controlgear--Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV.
  • Référence: CENELEC EN 50069, High-voltage switchgear and controlgear--Gas-filled welded composite enclosures of cast and wrought aluminium alloys.
  • Référence: IEC 62271-211, High-voltage switchgear and controlgear--Part 211: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV.
  • Référence: Fluid-filled and dry-type cable-terminations.
  • Référence: ANSI/NEMA CC 1, Electric Power Connection for Substations.
  • Référence: IEC 62271-1:2017, High-voltage switchgear and controlgear--Part 1: Common specifications for alternating current switchgear and controlgear.
  • Référence: IEC 62271-102:2018, High-voltage switchgear and controlgear--Part 102: Alternating current disconnectors and earthing switches.