Revision Standard - Superseded. Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene–propylene rubber insulation, nitrile jacket, ethylene–propylene diene monomer (EPDM) jacket or lead sheath, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 140 ºC (284 ºF) for nitrile or a maximum of 232 ºC (450 ºF) for EPDM jacket or lead sheath cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.

Spécifications des produits

  • Standard de IEEE
  • Publié:
  • Type de document: IS
  • Pages
  • Editeur: IEEE
  • Distributeur: IEEE
  • ICS: 29.060.20
  • Comité national: IEEE Industry Applications Society / Petroleum and Chemical Industry

Relations produit

  • Révisé par: IEEE 1017.2-2021
  • Référence: IEEE 1017-2013
  • Révise: IEEE 1018-2004
  • Référence: API RP 11S5, Recommended Practice for Application of Electric Submersible Cable Systems.
  • Référence: ASTM A90, Standard Test Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or
  • Référence: API RP 11S3, Recommended Practice for Electric Submersible Pump Installations.
  • Référence: ANSI/NEMA WC 71/ICEA S-96-659, Standard for Nonshielded Cables Rated 2001 – 5000 Volts for Use in the Distribution of Electric Energy.
  • Référence: ASTM B8, Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard,
  • Référence: ASTM B33, Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes.
  • Référence: ASTM B189, Standard Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for
  • Référence: ASTM B496, Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors.
  • Référence: API RP 11S6, Recommended Practice for Testing of Electric Submersible Pump Cable Systems.
  • Référence: API RP 11S4, Recommended Practice for Sizing and Selection of Electric Submersible Pump Installation.
  • Référence: ASTM B3, Standard Specification for Soft or Annealed Copper Wire.
  • Référence: Zinc-Alloy Coatings.
  • Référence: or Soft.
  • Référence: Electrical Purposes.