Standard

SAE 2008-01-2509

Actuel
Aperçu L'aperçu n'est pas disponible

Amendements et versions existants ou nouveaux doivent être achetés séparément.

Langue
Format

Résumé

An HPLC (High Performance Liquid Chromatography) method to measure the concentration of six organic acids in E-85 fuel has been developed. A three point calibration curve is established using standard solutions of the following organic acids: formic acid, acetic acid, propionic acid, butyric acid, glycolic acid and citric acid. An internal standard (maleic acid) is used to monitor HPLC system suitability and peak retention time stability. The method utilizes UV detection at 210 nm to detect and quantify the levels of each acid in E-85 fuel. Test results from nine commercially available E-85 fuel samples are reported. Analytical method validation was achieved by performing and confirming system suitability or injection repeatability (percent relative standard deviation ≤ 3%), calibration curve linearity (R 2x ≥ 0.999), analysis repeatability (standard deviation < 1 mg/L) and recovery (percent recovery 91 - 102%). The minimum detectable level was determined to be less than 1.5 mg/L for each acid.

Spécifications des produits

  • Standard de SAE International
  • Publié:
  • Type de document: IS
  • Pages
  • Editeur: SAE International
  • Distributeur: SAE International