This specification covers nickel-iron-chromium-molybdenum-columbium stabilized alloy (UNS N08700) bar. The final treatment of the material shall be a solution anneal. Straightening or cold finishing, or both, may be performed after the final solution annealing operation. Cold drawing to more than a minor sizing reduction after the final solution annealing is not recommended. Heat analysis shall conform to the requirements as to chemical composition prescribed. Tensile strength, yield strength, and elongation shall conform to the mechanical property requirements of the material as set by this specification. Test methods such as corrosion test, chemical analysis, tension test, and rounding procedure test shall be carried out.