This paper analyzes the potential benefit of a model based DPF leakage monitor over a conventional DPF leakage monitor that checks pressure drop after a complete regeneration. We analyze the most important noise factors involved in both approaches and demonstrate that the model based leakage monitor does not improve on the conventional leakage monitor in accuracy. It does improve on completion frequency, but at the expense of a great modeling effort.